Strep-Tactin® column formats



Column, cartridge and plate formats

For Strep-Tactin® resins

No Description Application
Volume applied**
Strep-Tactin® Sepharose®
Strep-Tactin® Superflow®
Strep-Tactin®
Superflow®
high capacity
Strep-Tactin® MacroPrep®
Strep-Tactin®
POROS 20
1 0.2 ml gravity
flow columns
(5 columns)
Gravity flow 0.1 - 2 ml 2-1202-550 2-1207-550 2-1209-550 2-1506-550
2 1 ml gravity
flow column
Gravity flow 0.5 - 10 ml 2-1202-001 2-1207-001 2-1209-001 2-1506-001
3 5 ml gravity
flow column
Gravity flow 2.5 - 50 ml 2-1202-051 2-1207-051 2-1209-051 2-1506-051
3 10 ml gravity
flow column
Gravity flow 5 - 100 ml 2-1202-101 2-1207-101 2-1209-101 2-1506-101
4 1.7 ml HPLC
column
HPLC 0.85 - 17 ml 20: 2-1203-017
50: 2-1205-017
5 NEW! 1 ml
H-PR cartridge
FPLC/HPLC 0.5 - 10 ml 2-1231-001 2-1233-001 2-1531-001
5 NEW! 5 ml
H-PR cartridge
FPLC/HPLC 2.5 - 50 ml 2-1232-001 2-1234-001 2-1532-001
6 Spin Columns
(50 columns,
for 150 μg
protein each)
Spinning Up to 500 μl 2-1850-050
(Kit: 2-1800-000)
7 Strep-Well HT
25 plates (10 x
96well plates, for 100 μg protein/well)
High
throughput/
Vacuum
based
50 μl - 1 ml 2-1725-010
(Kit: 2-1700-
000
7 Strep-Well HT
50 plates (10 x
96well plates, for 200 μg protein/well)
High
throughput/
Vacuum
based
50 μl - 1 ml 2-1750-011
(Kit: 2-1701-
000
)

Adjust protein extract volume according to binding capacity of the column, see resin specifications.



Columns for purification of Strep-tag proteins under gravity flow


Gravity flow column with 0.2 ml Strep-Tactin resin.
Gravity flow column with 1 ml Strep-Tactin resin. Also available with Ni-NTA resin.
Gravity flow columns with 5 ml and 10 ml Strep-Tactin resin; 5 ml column also available with Ni-NTA resin.

Note: The gravity flow columns illustrated here are pre-packed with Strep-Tactin Sepharose


Column sizes: 0.2 ml, 1 ml, 5 ml and 10 ml
Strep-Tactin resins: Strep-Tactin Sepharose®, Strep-Tactin Superflow® and Strep-Tactin Macroprep®
.
Please note that 1ml and 5 ml gravity flow columns are available also with Ni-NTA resins

 

Column evaluation Sets

Evaluation Set Our Column Evaluation Sets enable the comparison of the three different resins. Available for two gravity flow column sizes.


Handling and regeneration of Strep-Tactin gravity flow columns

Gravity flow columns cannot run dry allowing a step-by-step purification procedure without the need for further equipment. After purification, columns are regenerated with a yellow regeneration buffer containing 1 mM HABA (2-[4'-hydroxy-benzeneazo] benzoic acid. The regeneration process on the column can be followed visually by color change from yellow to red. Prior to the next run the dye is washed off with fast kinetics by equilibration buffer. Please note, that MacroPrep and POROS* do not turn as red as Sepharose (see Strep-Tactin Resins-Specifications) and may keep a slight pink color after regeneration. The binding, elution and regeneration process is described in detail here.
For details please refer to the Strep-tag manual (pdf, 1295 KB).
Evaluation Set

Strep-Tactin columns regenerated with HABA (see also Strep-tag purification cycle):
Strep
-Tactin MacroPrep, Superflow and Sepharose (left to right). Since MacroPrep is not as transparent as Sepharose or Superflow, the color shift to red is less visible. Scale: reduced.

*Color change not visible on non-transparent FPLC/HPLC columns.




Cartridges and columns for purification of Strep-tag proteins with HPLC/FPLC, syringes or with peristaltic pumps

H-PR cartridges (Äkta compatible) Pre-packed column with Strep-Tactin POROS®.


H-PR cartridges:
The H-PR cartridges are primarily designed for use with chromatography workstations with 10-32 connections (please note that you do not need adapters for HPLC and Äkta). They can, however, also be operated with other workstations, with syringes or with peristaltic pumps by use of common adapters for H-PR cartridges. Since column bodies are highly pressure resistant ("H-PR") and can tolerate 20 bar, the H-PR cartridges can be used with a flow restrictor. Cartridges can be connected in series to enlarge capacity. H-PR cartridges are available with Strep-Tactin Superflow® (1 and 5 ml size) and Strep-Tactin Macroprep® (1 and 5 ml size). They are also available with Ni-NTA resins.

Strep-Tactin POROS® columns, pre-packed column with Strep-Tactin POROS® 20 or 50, 1.7 ml bed volume, for HPLC/FPLC. Stable to high pressure (~170bar).

(Please note, for questions regarding our former Luer-lock cartridges contact info@iba-go.com )

Adapters for cartridges

Adapters for H-PR cartridges are available for use with syringes and for connection to peristaltic pump chromatography systems or FPLC/HPLC workstations. Please note that no adapters are needed for connection of H-PR cartridges to Äkta systems or 10-32 connections.


Adapters for H-PR cartridges

Syringe adapter set (Luer-lock) for H-PR cartridges, 3 sets
Contains: 3x "Female Luer to 10-32 Male" and 3x "1/16 Barb to 10-32 Male"
M6 adapter set for H-PR cartridges, 1 set
Contains: 2x "Female Peek M6 to 10-32 Male"
1/4-28 adapter set for H-PR cartridges, 1 set
Contains: 2x "Female Peek 1/4-28 to 10-32 Male"
1/16 inch adapter set for H-PR cartridges, 3 sets
Contains: 6x "1/16 Barb to 10-32 Male"
Coupling adapter set for connecting up to three H-PR cartridges
Contains: 2 adapters 10-32 Male

(Please note, for questions regarding our former Luer-lock cartridges contact info@iba-go.com )





Order information
see also "how to order"


adapter sets for H-PR cartridges amount cat. no. order & prices
Syringe adapter set (Luer-lock) for H-PR cartridges 3 sets 2-1021-001 online order 
M6 adapter set for H-PR cartridges 1 set 2-1022-001 online order 
1/4-28 adapter set for H-PR cartridges 1 set 2-1023-001 online order 
1/16 inch adapter set for H-PR cartridges 3 sets 2-1025-001 online order
Coupling adapter set for connecting up to three H-PR cartridges 2 adapters 2-1026-001 online order






Spin columns

Spin columns for rapid purification of Strep-tag proteins

Strep-Tactin Spin Columns




High-throughput

High-throughput purification of Strep-tag proteins

Strep-Well HT Purification Plate with immobilized Strep-Tactin for high-throughput protein purification.



Need buying or technical advice?
Contact a protein expert!
  • +49(0)551 50672-0
  • Online
  • E-mail (please indicate your complete address)



top